User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
Installation RF-Orchestra!™ Transmitter Installation and Operation
4-6 6880493G02-C July 2000
Recommended Parts
The following table lists the recommended parts for installation. These parts are not included
as part of the RF-O! paging station shipment and must be procured locally (see Table 4-3).
Cabinet Installation
The following information provides procedures for installing the equipment cabinets at a site
selected by the paging service provider. The procedures assume that all prerequisites are
satisfied and the site is ready for equipment installation. All antenna cables, power outlets,
and ground wires must be in place before installing the RF-O! paging station cabinet.
Cabinet
All equipment cabinets are equipped with casters. The two front casters have locks that must
be unlocked before moving the cabinet. Relock the casters after positioning the cabinet.
Table 4-3: Recommended Parts for Installation
Part Type/Size Manufacturer Where used
Anchor kit #2100-13 Hendry Cabinet floor anchors
Colored vinyl tape Red, black, green,
brown, yellow, and white
Locally procured Wire identification
Ground cables #2 AWG stranded
copper [(Cu) green]
#6 AWG stranded
copper [(Cu) green]
Locally procured
Locally procured
Cabinet grounding
Cabinet grounding
Ground wire #4 AWG bare solid Locally procured Cabinet grounding
Split nuts No specific model
recommended
Locally procured Join grounds
Lifting eyes Locally procured Lifting cabinets
Floor anchor kit Locally procured Anchoring cabinets