RF-Orchestra!™ Transmitter Installation and Operation Preinstallation
July 2000 6880493G02-C 3-9
Figure 3-3: Top View of RF-O! Paging Station
The ground wire should drop into the Ground location at the top of the cabinet and be
connected to a single dedicated grounding stud. Single hole lugs (0.5 in.(1.27 cm) diameter)
are used for these grounding connections (see Figure 3-3).
CAUTION
Do not daisy chain multiple cabinet grounds using a single ground wire. Doing so
increases the overall inductance of the ground wire, which can distribute surge energy
among the cabinets instead of to the master ground bus.
302SRH-75
Ground Block
Side View
Top View
Site Ground Wire