Equipment Cabinet Floor Loading
Table 3-2 shows the typical weight and floor loading information for the X128 cabinet.
Transmitter Breaker Panel Access
Follow all codes required by the National Electrical Code (NEC). The NEC requires a 36-in.
clearance for electrical service access, and requires that all doors to this equipment open to a
minimum of 90 degrees.
Disabled Personnel
The customer is responsible for determining the applicable Americans with Disabilities
Act (ADA) requirements that apply to the site. The ADA requires certain clearances for
handicapped personnel.
Table 3-2: Equipment Cabinet Weight and Floor Loading - Cabinet X128
Configuration Weight
1
1. Weights include optional transmitter and network peripherals. If a co-located RF-A! receiver is supplied, weights
include receiver peripherals
Floor Loading
Model PT1052 Single-channel RF-O! Transmitter
520 lb
236.36 kg
116 lb/ft
2
5.8 kg/m
2
Model PT1054 Two-channel RF-O! transmitter
590 lb
268.18 kg
132 lb/ft
2
6.6 kg/m
2
Model PT1052 One-channel RF-O! transmitter with Option X349
(Single Co-located RF-A! Receiver)
605 lb
275 kg
135 lb/ft
2
6.75kg/m
2
Model PT1054 Two-channel RF-O! transmitter with Option X351
(Two Co-located RF-A! receivers)
715 lb
325 kg
160 lb/ft
2
8 kg/m
2