User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation System Description
July 2000 6880493G02-C 2-35
Figure 2-17: AC Service Connection Using NEMA L15-20P (Nonpreferred Method)
Electrical requirements (InFLEXion and ReFLEX) are in Table 2-8 and Table 2-9 respectively.
Table 2-6: InFLEXion Electrical Requirements
Configuration AC Amps
1
1. AC amps maximum steady-state operation is current at 195 Vac input. Each RF-O! transmitter configuration is at 75-W
average RF output for each subchannel operation. AC amps start-up is 120 A.
BTU/Hour
Heat Load
(Maximum)
Model PT1052 Single-channel transmitter 6.4 5,400
Model PT1054 Two-channel RF-O! transmitter 11.2 6,860
Model PT1052 Single-channel RF-O! transmitter with Option X349
(Single co-located RF-A! receiver)
6.7 5,611
Model PT1054 Two-channel RF-O! transmitter with Option X351
(Two Co-located RF-A! receivers)
11.8 7,230
Black 120 V
White 0 V
Red 120 V
Green
120 V
208 V
120 V
AUX
ACC
TX
302SRH
-
72
NEMA L15-20P
X
Y
GW
X
Y
G
W