User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation System Description
July 2000 6880493G02-C 2-31
General Specifications
General specifications such as power, frequency, modulation, and control are in Table 2-5.
Table 2-5: General Specifications (Sheet 1 of 2)
Specification Value
Input Power
Power Supply Type Switching
AC Power 196–254 Vac @ 47–63 Hz nominal; 30 A; load sharing sized IAW PA
Battery Revert Control Only
TX Frequency
Carrier Frequency Range 929-941 MHz
Channel Switch Time Exceeds InFLEXion Protocol specifications
Frequency Generation Synthesized—5 and 6.25 kHz steps
Channel Spacing 50 kHz NPCS Channels
Conducted Spurious less than –80 dBc
Harmonic Emissions less than –100 dBc
Adjacent Channel Noise Exceeds FCC Mask; part 24
Frequency Deviation (2/4-level) IAW ReFLEX and InFLEXion specifications
Frequency Offsets and Deviation
Adjust
+5000 Hz, programmable in 1 Hz steps
Frequency Stability (UHSO)
+005 ppm –30 °C to +60 °C (-22 °F to +140 °F)
Isolation (built-in circulator) 20 dB standard, 3 choices of Tx peripherals to meet site needs
FM Hum and Noise –40 dB; 300 to 3000 Hz
Emissions Designators 6K25B8E, 600F1D
Deviation Accuracy
+1 Hz
TX Modulation
Pager Signaling
2-level and/or 4-level binary FSK-NRZ FLEX, ReFLEX, and InFLEXion
codes