User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
July 2000 6880493G02-C H-15
RF-Orchestra!™ Transmitter Installation and Operation Debug Traces
July 2000 6880493G02-C H-15
SHMI 2 1.4.0+ Ambient Temperature Trace
Displays data from ambient temperature
sensor located on the OCM module behind
the front panel LED’s.
A/D
: Analog to Digital reading (0 to 255).
Volt
: Converted A/D reading to a voltage (0
to 5 V DC)
Curr
: Current Temperature. Converted from
A/D reading.
Filt
: Running average of all ambient
temperature readings.
Thresh
: PA temperature at which the
transmitter will begin cutting back. (Param
1025 plus the average ambient temperature
reading (Filt:))
Ambient Temp- A/D: 99, Volt: 3.00VDC, Curr: 026C, Filt: 026C, Thresh: 056C
Ambient Temp- A/D: 9a, Volt: 3.02VDC, Curr: 028C, Filt: 026C, Thresh: 056C
Ambient Temp- A/D: 98, Volt: 2.98VDC, Curr: 025C, Filt: 026C, Thresh: 056C
Ambient Temp- A/D: 98, Volt: 2.98VDC, Curr: 025C, Filt: 026C, Thresh: 056C
SHMI 4 1.4.0+ PA Temperature Trace. Displays data
related to the PA and ambient temperature
readings.
A/D
: Analog-to-digital reading from PA
thermistor (0 to FF hex).
Temp
: Temperature converted from A/D
reading in degrees Centigrade.
Curr
: Current ambient temperature read on
OCM board.
Filt
: Running average of all ambient
temperature readings.
Thresh
: PA temperature at which the
transmitter will begin cutting back. (Param
1025 plus the average ambient temperature
reading (Filt:))
(Single PA Display)
PA 1 Temp- A/D: cf, Temp: 027C, Curr: 028C, Filt: 026C, Thresh: 056C
PA 1 Temp- A/D: cf, Temp: 027C, Curr: 028C, Filt: 026C, Thresh: 056C
PA 1 Temp- A/D: cf, Temp: 027C, Curr: 028C, Filt: 026C, Thresh: 056C
PA 1 Temp- A/D: cf, Temp: 027C, Curr: 025C, Filt: 026C, Thresh: 056C
PA 1 Temp- A/D: ce, Temp: 028C, Curr: 026C, Filt: 026C, Thresh: 056C
Table H-2: Traces
Trace Flag Version Description Example Output