User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
H-10 6880493G02-C July 2000
Debug Traces RF-Orchestra!™ Transmitter Installation and Operation
H-10 6880493G02-C July 2000
MPCM 2 1.4.0+ Maintenance Path Inbound Data Trace
Displays incoming message as is, i.e., in hex
bytes with all framing present. This
message should be exactly what was
received over the MP from the controller
<MPCM 2> INPUT DATA (Hex): 10 02 4E 83 4E 22 10 03
<MPCM 2> INPUT DATA (Hex): 10 02 4E 84 4E 23 10 03
<MPCM 2> INPUT DATA (Hex): 10 02 4E 85 4E 24 10 03
<MPCM 2> INPUT DATA (Hex): 10 02 4E 86 4E 25 10 03
<MPCM 2> INPUT DATA (Hex): 10 02 4E 87 4E 26 10 03
MPCM 4 1.4.0+ Maintenance Path Control Line Status
Displays the control line status (TX OK and
RFC Request) whenever it changes, as
reported to the MPCM task by the Station
Hardware Manager Interface (SHMI) Task.
<MPCM 4> CONTROL LINE: Status: TX OK Line Up
<MPCM 4> CONTROL LINE: Status: TX OK Line Down
<MPCM 4> CONTROL LINE: Status: TX OK Line Up
<MPCM 4> CONTROL LINE: Status: TX OK Line Down
<MPCM 4> CONTROL LINE: Status: TX OK Line Up
MPCM 8 1.4.0+ Maintenance Path Event or Parameter
Update Trace. Displays each queue
message to the MPCM with a parameter
update or an event. ParamId: (hex)
Parameter Manager ID (0x64 = 100)
Value
:
Event Report
EventId
:
Alarm Status
:
Event Desc
: Description of event being
reported.
<MPCM 8> EV/PARAM UPDT: ParamId: 0x64 Value: Unknown Parameter
<MPCM 8> EV/PARAM UPDT: ParamId: 0x63 Value: Unknown Parameter
<MPCM 8> EV/PARAM UPDT: EventId: 0x12 Alarm Status: F
Event Desc: Paging Disabled Alarm
<MPCM 8> EV/PARAM UPDT: EventId: 0x12 Alarm Status: F
Event Desc: Paging Disabled Alarm
Table H-2: Traces
Trace Flag Version Description Example Output