User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
H-4 6880493G02-C July 2000
Debug Traces RF-Orchestra!™ Transmitter Installation and Operation
H-4 6880493G02-C July 2000
Table H-2: Traces
Trace Flag Version Description Example Output
COHQ 1 1.4.0+ Launch Time and Synthesizer Trace.
Displays data being sent to the collector
DSP based on the control command just
received from the distributor DSP.
Synth
: Synthesizer to be used (0 or 1)
Coarse
: Coarse Launch Time
Fine
: Fine Launch Time
ChanlFilter
: Channel splatter filter to be
used (000 - 50 kHz, 001- 25 kHz).
<COHQ 1>LAUNCH TIME: Synth:0x0 Coarse:0x0000b7c0 Fine:0x01
ChanlFilter:0x000
<COHQ 1>LAUNCH TIME: Synth:0x0 Coarse:0x00005dc0 Fine:0x01
ChanlFilter:0x000
COHQ 2 Reserved.
DIAG 1 1.4.0+ Diagnostics Error Log Trace
Displays errors to the FIPS port as they are
logged in the A 104 or A 110 log. Useful for
monitoring the order and time at which
errors are logged.
Currently not functional.
DIDQ 1 1.4.0+ Start Time Error. Information useful in
debugging the cause of
E_START_TIME_ERROR. Only displays
data when error occurs.
DIDQ 2 1.4.0+ Incomplete Frame Error. Information useful
in debugging the cause of
E_INCOMPLETE_FRAME_ERROR. Only
displays data when error occurs.
DIDQ 4 1.4.0+ Modulation Type Error. Information useful in
debugging the cause of
E_MODULATION_TYPE_ERROR. Only