User Manual

Table Of Contents
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-32 6880493G02-C July 2000
High External Wattmeter VSWR (Greater than 3.0). E_HIGH_EXT_WM_VSWR_ALARM
High Internal Wattmeter VSWR (Greater than 3.0). E_HIGH_INT_WM_VSWR_ALARM
PA 1 A to D Converter 1 Test Voltage Failure. E_PA_AD_1_TEST_VOLTAGE_FAIL_DECK_1
PA 2 A to D Converter 1 Test Voltage Failure. E_PA_AD_1_TEST_VOLTAGE_FAIL_DECK_2
PA 1 Power Supply A to D Converter Test Voltage
Failure.
E_PA_AD_2_TEST_VOLTAGE_FAIL_DECK_1
PA 2 Power Supply A to D Converter Test Voltage
Failure.
E_PA_AD_2_TEST_VOLTAGE_FAIL_DECK_2
PA Failure. Transmitter Shutdown. (See FIPS: A 83) E_PA_FAIL_SHUTDOWN_ALARM
PA or PS Failure. Transmitter Cutback. (See FIPS:
A 83)
E_PA_FAIL_CUTBACK_ALARM
PnP Check Command Frequency Mismatch. E_CHECK_COMMAND_FREQ_FAIL
PnP Check Command Station Key State Mismatch. E_CHECK_COMMAND_KEY_FAIL
Power Amplifier 1 Operating Temperature Has
Exceeded Specification.
E_PA_HS_TEMPERATURE_FAIL_DECK_1
Power Amplifier 2 Operating Temperature Has
Exceeded Specification.
E_PA_HS_TEMPERATURE_FAIL_DECK_2
Power Amplitude Not Aligned. Transmitter
Shutdown.
E_AMPLITUDE_NOT_ALIGNED
Power Output is Above the Limit on the External
Reflected Power Meter
E_EXTERNAL_REFLECTED_POWER_HIGH
Power Output is Above the Limit on the Internal
Reflected Power Meter
E_INTERNAL_REFLECTED_POWER_HIGH
Power Output is Below the Limit on the External
Forward Power Meter
E_EXTERNAL_FORWARD_POWER_LOW
Power Output is Below the Limit on the Internal
Forward Power Meter
E_INTERNAL_FORWARD_POWER_LOW
Power Output Too High/Low to Auto Level. Check
Wattmeter Calibration.
E_POWER_LEVELING_FAILED
Table F-4: RF-O! Error Code / Alarm Code Cross Reference
Alarm Text (RFO FIPS: a 99) Corresponding Error Code (RFO FIPS: a 104)