User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-32 6880493G02-C July 2000
High External Wattmeter VSWR (Greater than 3.0). E_HIGH_EXT_WM_VSWR_ALARM
High Internal Wattmeter VSWR (Greater than 3.0). E_HIGH_INT_WM_VSWR_ALARM
PA 1 A to D Converter 1 Test Voltage Failure. E_PA_AD_1_TEST_VOLTAGE_FAIL_DECK_1
PA 2 A to D Converter 1 Test Voltage Failure. E_PA_AD_1_TEST_VOLTAGE_FAIL_DECK_2
PA 1 Power Supply A to D Converter Test Voltage
Failure.
E_PA_AD_2_TEST_VOLTAGE_FAIL_DECK_1
PA 2 Power Supply A to D Converter Test Voltage
Failure.
E_PA_AD_2_TEST_VOLTAGE_FAIL_DECK_2
PA Failure. Transmitter Shutdown. (See FIPS: A 83) E_PA_FAIL_SHUTDOWN_ALARM
PA or PS Failure. Transmitter Cutback. (See FIPS:
A 83)
E_PA_FAIL_CUTBACK_ALARM
PnP Check Command Frequency Mismatch. E_CHECK_COMMAND_FREQ_FAIL
PnP Check Command Station Key State Mismatch. E_CHECK_COMMAND_KEY_FAIL
Power Amplifier 1 Operating Temperature Has
Exceeded Specification.
E_PA_HS_TEMPERATURE_FAIL_DECK_1
Power Amplifier 2 Operating Temperature Has
Exceeded Specification.
E_PA_HS_TEMPERATURE_FAIL_DECK_2
Power Amplitude Not Aligned. Transmitter
Shutdown.
E_AMPLITUDE_NOT_ALIGNED
Power Output is Above the Limit on the External
Reflected Power Meter
E_EXTERNAL_REFLECTED_POWER_HIGH
Power Output is Above the Limit on the Internal
Reflected Power Meter
E_INTERNAL_REFLECTED_POWER_HIGH
Power Output is Below the Limit on the External
Forward Power Meter
E_EXTERNAL_FORWARD_POWER_LOW
Power Output is Below the Limit on the Internal
Forward Power Meter
E_INTERNAL_FORWARD_POWER_LOW
Power Output Too High/Low to Auto Level. Check
Wattmeter Calibration.
E_POWER_LEVELING_FAILED
Table F-4: RF-O! Error Code / Alarm Code Cross Reference
Alarm Text (RFO FIPS: a 99) Corresponding Error Code (RFO FIPS: a 104)