User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-31
Clearing the Error Logs on OCM (RFO FIPS: a 103)
Enter the RFO FIPS: a 103 command to clear the OCM Alarm Log. Turning off the RF-O!
transmitter, resetting the station using RFO FIPS: a 117 command, or pushing the RESET
button on the RF-O! transmitter will not clear the alarm logs.
RF-O! Error Code/Alarm Code Cross-Reference
The table below shows all of the currently supported RF-O! transmitter Alarms along with the
corresponding Error Log entry.
Table F-4: RF-O! Error Code / Alarm Code Cross Reference
Alarm Text (RFO FIPS: a 99) Corresponding Error Code (RFO FIPS: a 104)
16.8MHz Pendulum Reference Not Phase Locked. E_PENDULUM_NOT_LOCKED
16.8MHz Pendulum Reference Not Detected. E_PENDULUM_REFERENCE_FAILURE
Alarm Occurred Due to OCM Reset. S_STATION_RESET
Catastrophic Exciter Failure Detected. E_EXCITER_FRU_FAIL_ALARM
Circulator Load Temperature Limit Exceeded. E_CIRC_LOAD_TEMP_EXCEEDED
Clipping Detected by the Tranlin During FM
Transmission.
E_STATION_FM_CLIPPING_DETECTED
Clipping Detected by the Tranlin During Voice
Transmission.
E_STATION_AM_CLIPPING_DETECTED
Exciter Synthesizer 1 Has Failed to Lock. E_SYNTH1_LOCK_FAIL
Exciter Synthesizer 2 Has Failed to Lock. E_SYNTH2_LOCK_FAIL
Exciter Tranlin IC 236 MHz Oscillator Failed to
Lock.
E_TXLIN_NOT_LOCKED
Failed to Read A to D Converter using SPI on PA 1
Power Supply.
E_PA1_PS_AD_SPI_READ_FAIL
Failed to Read A to D Converter using SPI on PA 2
Power Supply.
E_PA2_PS_AD_SPI_READ_FAIL
Failed to Read the Exciter A to D Converter. E_EXCITER_AD_READ_FAIL