User Manual

Table Of Contents
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-26 6880493G02-C July 2000
I_PC_ENABLED_PARAMETER_WRITE_DISABLED)
An attempt to write to one or more of the Power
Amplitude Parameters was made while Power Control
(PC) was Enabled. This log entry is intended to inform
the user, that the values entered will not be recognized
by the RF-O! software while Power Control is Enabled,
but will be used by the station once/if Power Control is
Disabled.
NOTE: This error log entry will occur approximately 6
times if the “Initialize Amplitude Alignment” command
RFO FIPS: a 75) is entered while Power Control is
Enabled.
Informational
No Action Required.
It is important to note that while Power
Control is enabled, the RF-O! transmitter
uses calculated values for power
amplitude settings, not the values stored
in the Parameter Database. The
calculated values can be found using the
RFO FIPS: a 87 x command.
Attempting to write any of the following
parameters while Power Control is
Enabled will cause this message to be
logged:
Phase Training Scale (982), K-Factor
(990), Tranlin Attenuation Level (974),
Exciter Attenuator Level (953), Txlin
Attenuator (954), Exciter Feedback
Attenuator (996), Maximum Deviation
(2053),Modulation FM power (2054),
Modulation Voice Pilot Power (2055), or
Modulation Voice Sideband Power
(2056).
I_SIMULCAST_LAUNCH_DELAY_CHANGED
The Simulcast Launch Delay parameter (2049) was
changed during normal operation after bootup. The
RFO will disable paging and reaquire the 1PPS signal.
Informational
No action required.
Note: Paging will resume after 1PPS
signal is reaquired (usually around ten
seconds).
I_STATION_PA_DECK_FULL_POWER
(formerly E_STATION_PA_DECK_FULL_POWER)
Set when RF-O! transmitter goes from a cutback or
shutdown state to full power operation, due to recovery
from a PA failure.
Informational
If error occurs excessively, along with
E_STATION_PA_DECK_CUTBACK, or
E_STATION_PA_DECK_SHUT_DOWN,
this situation could indicate PA failures.
Verify proper PA and power supply
installation.Contact Motorola.
I_STATION_TEMP_FULL_POWER
(formerly E_STATION_TEMP_FULL_POWER)
Set when one or more PA’s has gone from a cutback
state, due to high temperature, back to full power
operation (temperature of PA decreased sufficiently to
allow full power operation to continue)
Informational
Excessive logging of this message with
E_STATION_PA_DECK_CUTBACK, or
E_STATION_PA_DECK_SHUT_DOWN
errors indicates PA operating temperature
problems.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 24 of 27)
Error and Description
Alarm
Severity
Action