Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-24 6880493G02-C July 2000
E_XILINX_DOWNLOAD_FAILURE
An error occurred while attempting to download a
program to the Xilinx FPGA.
Critical
Reset RF-O! transmitter. If error occurs
again, contact Motorola.
I_CUTOVER_TO_BANK_1_SUCCESSFULLY
The cutover to flash bank A after a remote software
download was performed.
Informational No action necessary.
I_CUTOVER_TO_BANK_2_SUCCESSFULLY
The cutover to flash bank B after a remote software
download was performed.
Informational No action necessary.
I_DIP1_ACTIVE_BUT_IGNORED
During reboot, the DIP Switch 1 on the RF-O!
transmitter module was detected as ON. However,
since DIP2 was detected as OFF, the DIP1 was
ignored.
Informational
Set the DIP switch to OFF unless
performing a parameter database reset.
I_DIP1_IS_ACTIVE
During reboot, the DIP Switch 1 on the RF-O!
transmitter module was detected as ON.
Informational
Set the DIP switch to OFF unless
performing a parameter database reset.
I_DIP1_NOT_SET
During reboot, the DIP Switch 1 on the RF-O!
transmitter module was detected as OFF.
Informational No action necessary.
I_DIP2_IS_ACTIVE
During reboot, the DIP Switch 2 on the RF-O!
transmitter module was detected as ON.
Informational
Set the DIP switch to OFF unless
performing a parameter database reset.
I_DIP2_NOT_SET
During reboot, the DIP Switch 2 on the RF-O!
transmitter module was detected as OFF.
Informational No action necessary.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 22 of 27)
Error and Description
Alarm
Severity
Action