User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-23
E_TXLIN_NOT_LOCKED
The Oscillator on the Exciter Txlin failed to lock. The
transmitter is disabled.
Critical
Verify that Exciter and OCM are properly
installed in the chassis. Error could
indicate problem with Exciter, backplane,
and/or OCM. Contact Motorola.
E_TXLIN_REGISTER_WRITE_FAIL
Indicates that an attempt to write one or more of the
Txlin registers using the SPI bus has failed. Failure to
properly write the Txlin registers may cause severe
transmitter failure.
Critical
Verify that Exciter and OCM are properly
installed in the chassis. Error could
indicate problem with Exciter, backplane,
and/or OCM. Contact Motorola.
E_UNABLE_TO_START_TASKS
OS Error: An attempt to start one of the Station
Software Tasks has failed.
Critical
Reset RF-O! transmitter. If the error
returns, contact Motorola.
E_UNDEFINED_1PPS_STATUS
The Collector DSP has returned a 1PPS status that
does not match any of the statuses known to the host.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_ELSE
The software took an undesired branch in a conditional
statement.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_OPCODE
A command passed to a task was not recognized by
that task.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_SYMBOL_COMMAND_ERROR
Sent if a symbol data command arrives before a control
command on Plug-and-Play data path.
Major
If the error persists, save the error log and
contact Motorola.
E_VARIABLE_OUT_OF_RANGE
Variable passed to a routine was outside its allowed
limits.
Informational
Debug message. Verify proper format of
all FIPS commands. If the error persists,
save the error log and contact Motorola.
E_WORK_AHEAD_WINDOW_ERROR
PnP Error: Sent if the arrival of the Plug-and-Play
packet is outside the designated arrival window.
Major
A few of these errors per day is normal in
a heavy traffic environment.
If excessive amounts of these errors are
logged, save the error log and contact
Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 21 of 27)
Error and Description
Alarm
Severity
Action