User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-23
E_TXLIN_NOT_LOCKED
The Oscillator on the Exciter Txlin failed to lock. The
transmitter is disabled.
Critical
Verify that Exciter and OCM are properly
installed in the chassis. Error could
indicate problem with Exciter, backplane,
and/or OCM. Contact Motorola.
E_TXLIN_REGISTER_WRITE_FAIL
Indicates that an attempt to write one or more of the
Txlin registers using the SPI bus has failed. Failure to
properly write the Txlin registers may cause severe
transmitter failure.
Critical
Verify that Exciter and OCM are properly
installed in the chassis. Error could
indicate problem with Exciter, backplane,
and/or OCM. Contact Motorola.
E_UNABLE_TO_START_TASKS
OS Error: An attempt to start one of the Station
Software Tasks has failed.
Critical
Reset RF-O! transmitter. If the error
returns, contact Motorola.
E_UNDEFINED_1PPS_STATUS
The Collector DSP has returned a 1PPS status that
does not match any of the statuses known to the host.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_ELSE
The software took an undesired branch in a conditional
statement.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_OPCODE
A command passed to a task was not recognized by
that task.
Informational
Debug message. If the error persists,
save the error log and contact Motorola.
E_UNEXPECTED_SYMBOL_COMMAND_ERROR
Sent if a symbol data command arrives before a control
command on Plug-and-Play data path.
Major
If the error persists, save the error log and
contact Motorola.
E_VARIABLE_OUT_OF_RANGE
Variable passed to a routine was outside its allowed
limits.
Informational
Debug message. Verify proper format of
all FIPS commands. If the error persists,
save the error log and contact Motorola.
E_WORK_AHEAD_WINDOW_ERROR
PnP Error: Sent if the arrival of the Plug-and-Play
packet is outside the designated arrival window.
Major
A few of these errors per day is normal in
a heavy traffic environment.
If excessive amounts of these errors are
logged, save the error log and contact
Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 21 of 27)
Error and Description
Alarm
Severity
Action