User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-20 6880493G02-C July 2000
E_STATION_FM_CLIPPING_DETECTED
(formerly E_EXCITER_FM_CLIPPING_DETECTED)
The Exciter has indicated that it has clipped during an
FM transmission.
Beginning with RF-O! transmitter 1.2.2, when Power
Control is Enabled, this error condition will cause the
transmitter to be disabled.
Critical
Verify that RF-O! transmitter amplitude is
properly aligned to the correct FM output
power. Verify that Internal and External
Wattmeters are calibrated. These can be
checked by using the RFO FIPS: a 83
(Station Status) command. Verify that all
RF connections on the RF-O! transmitter
are properly connected. If condition
persists, contact Motorola.
E_STATION_KEYED_KEY_STATE_MISMATCH
This error occurs when the transmitter status is in the
inactive state, but it should be in an active state.
Major
If the error persists, save the error log and
contact Motorola.
E_STATION_KEYED_MOD_MODE_MISMATCH
The current modulation type is invalid in the keyed
state.
Major
If the error persists, save the error log and
contact Motorola.
E_STATION_KEYED_NEXT_PROTOCOL_INVALID
The next modulation type has not been received in the
key state.
Major
If the error persists, save the error log and
contact Motorola.
E_STATION_PA_DECK_FULL_POWER
(See “I_STATION_PA__DECK_FULL_POWER”)
Set during powerup to indicate that all PA’s decks have
been initialized correctly.
Informational Ignore.
E_STATION_TEMP_FULL_POWER
(See “I_STATION_TEMP_FULL_POWER”)
Set at startup to indicate that the RF-O! transmitter
initially detected PA’s running within proper
temperature range.
Informational Ignore.
E_SWITCH_DEFAULT
Software Error. The value passed to a software
conditional ‘switch’ statement did not match any of the
tested values. The severity of this error depends
upon where in the software this error is logged.
Informational
Minor
Major
Critical
If the error persists, save the error log and
contact Motorola.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 18 of 27)
Error and Description
Alarm
Severity
Action