User Manual

Table Of Contents
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-18 6880493G02-C July 2000
E_POWER_LEVELING_FAILED
Transmitter is disabled due to Power Leveling
attempting to Gain or Attenuate the set power by more
than 1.5 dB. Power Leveling, as indicated by parameter
2999, or using RFO FIPS: a83(Station Status), should
typically be no more than 0.5 or less than -0.5 dB.
OCM needs to be reset to enable transmitter.
Major
Verify Amplitude Alignment is valid (A 83).
Use RFO FIPS: a 192 SPCQ 16 and a
192 SPCQ 64 debug traces to monitor
power leveling and wattmeter readings.
If problem persists, Contact Motorola.
E_PS_INPUT_VOLT_ALARM_DECK_1
Power Supply 1 voltage detected has fallen below
specified limits, flagging a possible power supply
failure.
Major Replace Power Supply 1.
E_PS_INPUT_VOLT_ALARM_DECK_2
Power Supply 2 voltage detected has fallen below
specified limits, flagging a possible power supply
failure.
Major Replace Power Supply 2.
E_QFULL
OS Error: Cannot Send - Message queue full. The
severity of this message depends upon where in the
RF-O! software this error occurred.
Minor/Critical
May cause the RF-O! transmitter to reset.
If error returns, save error log and contact
Motorola.
E_RFCC_INVALID_CHAN_OFFSET
(See “E_INVALID_CHAN_OFFSET” )
An invalid sub-channel offset was received from the
Plug-and-Play Control Command.
Major
If the error persists, save the error log and
contact Motorola.
E_RFCC_INVALID_MOD_TYPE
(formerly E_RFCC_INVALID_MOD_TYPE)
An invalid Modulation Type was received from the Plug-
and-Play Control Command.
Major
If the error persists, save the error log and
contact Motorola.
E_RFCC_SYNTH1_LOCK_FAIL
(See “E_SYNTH1_LOCK_FAIL” )
The attempt to reprogram the First Exciter Synthesizer
failed.
Critical
Reboot RF-O! transmitter. If the error
persists, save the error log and contact
Motorola.
E_RFCC_SYNTH2_LOCK_FAIL
(See “E_SYNTH2_LOCK_FAIL” )
The attempt to reprogram the Second Exciter
Synthesizer failed.
Critical
Reboot RF-O! transmitter. If the error
persists, save the error log and contact
Motorola.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 16 of 27)
Error and Description
Alarm
Severity
Action