User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-16 6880493G02-C July 2000
E_PA_HS_TEMPERATURE_FAIL_DECK_1
Power amplifier 1 heat sink temperature exceeded the
ambient temperature of the OCM by more than the
amount specified by Parameter 1024 or 1025.
Beginning with RF-O! transmitter 1.2.2, when Power
Control is Enabled, exceeding parameter 1024 (PA vs.
Ambient Temp Shutdown Offset), the transmitter will
become disabled (shutdown) until the temperature of
the PA deck lowers sufficiently.
Major
Verify all fans are operational. Verify
proper settings of parameters 1024 and
1025. Verify proper calibration of Ambient
Temperature Sensor on OCM. (Check
current Ambient Temperature by reading
parameter Contact Motorola.
E_PA_HS_TEMPERATURE_FAIL_DECK_2
Power Amplifier 2 Heat Sink Temperature Has
Exceeded the Ambient Temperature of the OCM by
more than the amount specified by Parameter 1024 or
1025. See “PA_HS_TEMPERATURE_FAIL_DECK_1”
Major
See “PA_HS_TEMPERATURE_FAIL_
DECK_1”
E_PA_INITIALIZATION_FAILED
During startup, or when enabling Power Control, the
RF-O! transmitter software was unable to read the PA
EEPROM(s), and/or Analog to Digital Converters.
Major
Verify proper installation of PA deck(s)
and wiring. Verify all power supplies are
turned on and functioning. Verify PA SPI
cable is properly connected.
E_PA_TEMP_CUTBACK_ALARM
The temperature of a PA exceeded the Ambient
Temperature at the OCM temperature sensor, by more
than the configured 3 dB Cutback amount (See
Parameter 1025).
Major
Verify Ambient Temperature Sensor is
properly calibrated. Read Parameter
1026 to see current ambient temperature
reading (if it appears too low, shutdown
may not be warranted). Use RFO FIPS: a
192 SHMI 4 trace to see PA and Ambient
Temperature readings. Verify fans are
working properly.
E_PA_TEMP_SHUTDOWN_ALARM
The temperature of a PA exceeded the Ambient
Temperature at the OCM temperature sensor, by more
than the configured Shutdown amount (See Parameter
1024).
Major
Verify Ambient Temperature Sensor is
properly calibrated. Read Parameter
1026 to see current ambient temperature
reading (if it appears too low, shutdown
may not be warranted). Use RFO FIPS: a
192 SHMI 4 trace to see PA and Ambient
Temperature readings.
Verify fans are working properly.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 14 of 27)
Error and Description
Alarm
Severity
Action