RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-15
E_MP_OUT_OF_SYNC_REPLY
Received sequence number is incorrect. BCM and
OCM are out of sync. Possible maintenance path
incompatibility between RF-O! transmitter and RF-B!
transmitter controller.
Minor
Reset RF-B! transmitter controller to
resynchronize the interface. If error
persists, contact Motorola.
E_MP_SOURCE_TASK_ID_NOT_FOUND
Source task ID received does not exist. Possible
maintenance path incompatibility between RF-O!
transmitter and RF-B! transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_UNEXPECTED_REPLY_OPCODE
The opcode received from the BCM is not recognized.
Possible maintenance path incompatibility between
RF-O! transmitter and RF-B!.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_VALUE_OVERFLOW
There were too many Parameter changes (values) that
occurred within the last 3 seconds for the PnP
Maintenance Path to transmit all of them to the
Controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_NOBUF
OS Error: Operating System is unable to obtain free
memory buffers for some form of messaging. There are
many locations in the RF-O! transmitter software where
this error may occur. Depending upon the location, the
severity of this error may vary.
Minor/Critical
If the error persists, save the error log and
contact Motorola.
E_NOT_ENOUGH_MEMORY
An attempt to allocate additional dynamic memory for a
FIPS reply message failed.
Minor
If the error persists, save the error log and
contact Motorola.
E_OVERWRITING_MOD_MODE_PARAMETERS
This error occurs when a new modulation type is
received by the RF-O! transmitter, while another
modulation type is pending transmission.
Major
If the error persists, save the error log and
contact Motorola.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 13 of 27)
Error and Description
Alarm
Severity
Action