User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-14 6880493G02-C July 2000
E_MP_INVALID_EVENT_ID
Event ID requested does not have an associated entry
in the event table. Possible maintenance path
incompatibility between RF-O! transmitter and RF-B!
transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_INVALID_EVENT_LENGTH
The error string exceeds the maximum number of
characters allowed. Error in table entry. Possible
maintenance path incompatibility between RF-O!
transmitter and RF-B! transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_INVALID_VALUE_DESC_ENUM_LENGTH
The enumeration length of an enumerated type
exceeds the maximum size allowed. Error in table
entry. Possible maintenance path incompatibility
between RF-O! transmitter and RF-B!.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_INVALID_VALUE_DESC_ID
Value ID requested does not have an associated
description in the value table. Possible maintenance
path incompatibility between RF-O! transmitter and
RF-B! transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_INVALID_VALUE_ID
Value ID requested does not have an associated entry
in the value table Possible maintenance path
incompatibility between RF-O! transmitter and RF-B!
transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_INVALID_VALUE_LENGTH
The value length does not match the associated value
format. Error in table entry. Possible maintenance path
incompatibility between RF-O! transmitter and RF-B!
transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
E_MP_NO_LAST_RESPONSE
There is no last response to return when the OCM
receives a request to send the last response. Possible
maintenance path incompatibility between RF-O!
transmitter and RF-B! transmitter controller.
Minor
If the error persists, save the error log and
contact Motorola.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 12 of 27)
Error and Description
Alarm
Severity
Action