User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-11
E_INVALID_COMMAND_TYPE_ERROR
PnP Error: Error occurs if Plug-and-Play message does
not match any possible Plug-and-Play commands.
Major
If error persists, contact Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
E_INVALID_FM_CONFIGURATION
This error occur during Power Control initialization,
during startup. There are two possible causes: (1)
There are no PA decks detected; (2) The current power
level was set out of range per the Power Chart.
NOTE: A software defect in RF-O! transmitter 1.2.2,
caused this error (along with
E_INVALID_AM_CONFIGURATION) to be logged
upon every reset. Ignore these errors in RF-O!
transmitter 1.2.2.
Major
Check PA configuration using RFO FIPS:
r 993. Set output power using RFO FIPS:
a 88 x y. If condition persists, contact
Motorola.
E_INVALID_FRAME_FLUSH_DSP_INDEX_ERROR
An illegal DSP designator was encountered by the DSP
Flush entire frame cycle.
Major
If error persists, save error log and
contact Motorola.
E_INVALID_IDLE_DSP_INDEX_ERROR
An illegal DSP designator was encountered by the DSP
Flush to IDLE cycle.
Major
If error persists, save error log and
contact Motorola.
E_INVALID_INFLEXION_DSP_INDEX_ERROR
An illegal DSP designator was encountered by the DSP
Flush to INFLEXION cycle.
Major
If error persists, save error log and
contact Motorola.
E_INVALID_INPUT_RECEIVED
An invalid input command is encountered in the key/
dekey cycle.
Major
If error persists, save error log and
contact Motorola.
E_INVALID_IPS_PORT
Host application attempted to connect to an invalid
communications port.
Informational Debug message only. Ignore.
E_INVALID_LAUNCH_TIME
An invalid Plug-and-Play launch time was received by
the host from the Distributor DSP.
Major
If the error persists, save the error log and
contact Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 9 of 27)
Error and Description
Alarm
Severity