User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Alarms and Error Messages
July 2000 6880493G02-C F-9
E_HIGH_INT_WM_VSWR_ALARM
RF-O! transmitter disabled the transmitter due to a
VSWR reading of greater than 3.0 (Reflected Power is
greater than one-fourth the Forward Power) at the
Internal Detector.
Critical
See
“E_INTERNAL_REFLECTED_POWER_
HIGH”
E_HIGH_STABILITY_REFERENCE_FAILURE
The OCM lost contact with the Ultra High Stability
Reference Oscillator (UHSO).
Critical
Verify RF-B! transmitter controller has
power. Verify reference module is
properly installed in RF-B! transmitter
controller. Verify 10 MHz BNC cable is
properly connected to both RF-O!
transmitter and RF-B! transmitter
controller on backplanes. Check that 10
MHz is signal is present on backplane. If
error persists, contact Motorola.
E_ILLEGAL_IPS_COMMAND
An invalid FIPS command was entered. The command
was ignored
Informational
If command was entered correctly, verify
that command is compatible with software
version. See FIPS document for correct
command formats.
E_ILLEGAL_PARAMETER_WRITE
The user tried to write a Parameter which can only be
written to by RF-O! transmitter software (Application
Write Only). Command was ignored.
Informational
Only attempt to write to writable
parameter ID’s. See FIPS document for
details.
E_ILLTICKS
OS Error: Ticks input out of range.
Minor
If error persists, save error log and
contact Motorola.
E_ILLTIME
OS Error: Time of day input out of range.
Minor
If error persists, save error log and
contact Motorola.
E_INCOMPLETE_FRAME_ERROR
The Distribution DSP has detected that a partial Frame
fragment was received. Possibly due to error in PnP
interface/protocol.
Major
If error persists, save error log and
contact Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 7 of 27)
Error and Description
Alarm
Severity
Action