User Manual

Table Of Contents
Alarms and Error Messages RF-Orchestra!™ Transmitter Installation and Operation
F-6 6880493G02-C July 2000
E_DSP_TX_MODE_INVALID_SOURCE_TASK
RF-O! transmitter host receives a DSP reply from a
source other than Distributor, Modulator, or Collector
DSP.
Minor
If error persists, save error log and
contact Motorola.
E_DSP_TX_MODE_INVALID_STATE
The DSP flush mode is in an invalid state.
Minor
If error persists, save error log and
contact Motorola.
E_DSP_TX_MODE_REPLIES_MISMATCH
The request mode sent to DSP does not match the
mode from the DSP reply.
Minor
If error persists, save error log and
contact Motorola.
E_DSP_TX_MODE_REQ_REPLY_OUT_OF_SEQ
RF-O! transmitter host receives invalid reply from DSPs
after sending a flush request
Minor
If error persists, save error log and
contact Motorola.
E_EEPROM_REPROG_PARMS_TO_DEFAULTS
The RF-O! transmitter software detected a new(blank)
or corrupted EEPROM.
Critical
The OCM EEPROM parameter database
has been reprogrammed and all
parameters have been set to default.
E_END_OF_COMMAND_ERROR
Sent if the Distributor DSP detects that the final word in
any PnP command has an invalid termination indicator.
Possible RF-O! transmitter/RF-B! transmitter controller
PnP incompatibility.
Minor
If error persists, save error log and
contact Motorola.
NOTE: This is a Plug-and-Play Error.
Transmitter was Disabled for 2 seconds,
and DSP buffers were flushed.
E_EXCITER_AD_READ_FAIL
RF-O! transmitter was unable to read the Exciter A/D
values using the SPI bus. Critical
Verify proper installation of Exciter and
OCM. Reset station. Error could indicate
a problem with the Exciter, backplane, or
OCM. If error persists, save error log and
contact Motorola.
E_EXCITER_EEPROM_READ_FAIL
The OCM was unable to read the data in the Exciter
Serial EEPROM using the SPI bus. The Exciter Serial
EEPROM contains the Internal and External Wattmeter
Calibration, and the Amplitude Alignment data
necessary for proper power output and leveling.
Major
Verify proper seating of Exciter and OCM
Module within the chassis. Clear error
logs, then reset OCM. Error could
indicate possible Exciter, backplane, and/
or OCM module failure.
If error persists, save error log and
contact Motorola.
Table F-3: RF-O! Transmitter Error/Alarm Code Definitions (Sheet 4 of 27)
Error and Description
Alarm
Severity
Action