User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation FIPS Read/Write Commands (ver. 2.0.0)
July 2000 6880493G02-C E-27
Ambient Temperature
Power Derate Start
r 3001
w 3001 <arg>
This defines the ambient temperature of the station
at which point the power control software starts to
derate (decrease) the power output.
80
C
30
C
45
C
Ambient Temperature
Power Shutdown
r 3002
w 3002 <arg>
This defines the ambient temperature of the station
at which point the power control software disables/
shuts down the station.
80
C
30
C
60
C
Ambient Temperature
Derate Maximum
Cutback
r 3003
w 3003 <arg>
This defines the amount of cutback the station will
linearly derate while the ambient temperature is
between the values of parameters 3001 and 3002.
10
dB
0.0
dB
3.0
dB
Programmed
Synthesizer 1
Frequency
r 3100
Value of the Synthesizer 1 Frequency that was
programmed with the RFO FIPS: a 165 command.
941000.0
kHz
928000.0
kHz
929000.0
kHz
Programmed
Synthesizer 2
Frequency
r 3101
Value of the Synthesizer 2 Frequency that was
programmed with the RFO FIPS: a 167 command.
941000.0
kHz
928000.0
kHz
929000.0
kHz
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 27 of 27)
Name and Command
Description
Ranges
Default
Upper Lower