User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation FIPS Read/Write Commands (ver. 2.0.0)
July 2000 6880493G02-C E-27
Ambient Temperature
Power Derate Start
r 3001
w 3001 <arg>
This defines the ambient temperature of the station
at which point the power control software starts to
derate (decrease) the power output.
80
C
30
C
45
C
Ambient Temperature
Power Shutdown
r 3002
w 3002 <arg>
This defines the ambient temperature of the station
at which point the power control software disables/
shuts down the station.
80
C
30
C
60
C
Ambient Temperature
Derate Maximum
Cutback
r 3003
w 3003 <arg>
This defines the amount of cutback the station will
linearly derate while the ambient temperature is
between the values of parameters 3001 and 3002.
10
dB
0.0
dB
3.0
dB
Programmed
Synthesizer 1
Frequency
r 3100
Value of the Synthesizer 1 Frequency that was
programmed with the RFO FIPS: a 165 command.
941000.0
kHz
928000.0
kHz
929000.0
kHz
Programmed
Synthesizer 2
Frequency
r 3101
Value of the Synthesizer 2 Frequency that was
programmed with the RFO FIPS: a 167 command.
941000.0
kHz
928000.0
kHz
929000.0
kHz
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 27 of 27)
Name and Command
Description
Ranges
Default
Upper Lower