User Manual

Table Of Contents
FIPS Read/Write Commands (ver. 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
E-26 6880493G02-C July 2000
Offset From Center
Frequency - Index 12
r 2112
w 2112 <arg>
Plug-and-Play Control Command Offset From
Center Frequency Index 12.
WARNING: This parameter intended for Lab/
Development use only!
50000
Hz
-50000
Hz
-25000
Hz
Offset From Center
Frequency - Index 13
r 2113
w 2113 <arg>
Plug-and-Play Control Command Offset From
Center Frequency Index 13.
WARNING: This parameter intended for Lab/
Development use only!
50000
Hz
-50000
Hz
-18750
Hz
Offset From Center
Frequency - Index 14
r 2114
w 2114 <arg>
Plug-and-Play Control Command Offset From
Center Frequency Index 14.
WARNING: This parameter intended for Lab/
Development use only!
50000
Hz
-50000
Hz
-12500
Hz
Offset From Center
Frequency - Index 15
r 2115
w 2115 <arg>
Plug-and-Play Control Command Offset From
Center Frequency Index 15.
WARNING: This parameter intended for Lab/
Development use only!
50000
Hz
-50000
Hz
-6250
Hz
Power Leveling
Cutback
r 2999
This parameter keeps track of the current power
leveling amount. When Power Control is enabled,
power leveling is automatically enabled. Typically,
this value should remain between -0.5 and 0.5. If this
value is outside of this range, possibly the Amplitude
Alignment and/or the Internal Wattmeter Calibration
is faulty.
Note: This value is set to 0 upon RF-O! reset.
4.00
dB
-4.00
dB
0
dB
Power Cutback
r 3000
This parameter maintains the current cutback
amount of the station in dB. If the station is shutdown
or disabled, this value is ignored by the RFO
software. Use RFO FIPS: a 83 to see the actual
station status.
Note: This value is set to 0 upon RF-O! reset.
10
dB
0
dB
0
dB
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 26 of 27)
Name and Command
Description
Ranges
Default
Upper Lower