RF-Orchestra!™ Transmitter Installation and Operation FIPS Read/Write Commands (ver. 2.0.0)
July 2000 6880493G02-C E-9
Ambient Temperature
Sensor Temperature
Calibration
r 1029
w 1029 <arg>
This is the temperature value used in calibrating the
station ambient temperature sensor.
(See Chapter 5, "Operation" for instructions on
calibrating the Ambient Temperature Sensor)
70
C
-30
C
25
C
Check Circulator Load
Thermal Switch
r 1030
w 1030 x
This parameter allows enabling/disabling the check
of the circulator load thermal limit. By default
checking is enabled (1). In certain instances in the
field an RF-O! may not have a circulator load thermal
switch installed, in which case, this parameter
should be set to disabled (0).
101
Peak-to-Average High
Soft Threshold 1
Subchannels
r 1100
w 1100 <arg>
Return/Set the value of Peak-to-Average High Soft
Threshold 1 Subchannel.
WARNING: This parameter intended for Lab/
Development use only!
32767 -32768 739
Peak-to-Average Soft
Threshold Constant 1
Subchannel
r 1101
w 1101 <arg>
Peak-to-Average Soft Threshold Constant 1
Subchannel
WARNING: This parameter intended for Lab/
Development use only!
32767 -32768 82
Peak-to-Average Low
Soft Threshold 1
Subchannel
r 1102
w 1102 <arg>
Return/Set the value of Peak-to-Average Low Soft
Threshold 1 Subchannel.
WARNING: This parameter intended for Lab/
Development use only!
32767 -32768 32767
Peak-to-Average High
Control Signal 1
Subchannel
r 1103
w 1103 <arg>
Return/Set the value of Peak-to-Average High
Control Signal 1 Subchannel.
WARNING: This parameter intended for Lab/
Development use only!
32767 -32768 -3277
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 9 of 27)
Name and Command
Description
Ranges
Default
Upper Lower