User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation FIPS Read/Write Commands (ver. 2.0.0)
July 2000 6880493G02-C E-7
Power Amplifier Deck
Configured
r 993
Number of operational PA decks detected by the
RFO software. 2 0 N/A
FM Power Output
r 994
Returns the current FM Power Output setting. This
value is modified using the RFO FIPS: a 88 0 x
command. (Actual Min/Max range of values depends
upon number of PA’s installed).
500 32 75
AM Power Output
r 995
Returns the current AM Power Output setting. This
value is modified using the RFO FIPS: a 88 1 x
command. (Actual Min/Max range of values depends
upon number of PA’s installed).
300 32 75
Exciter Feedback
Attenuation
r 996
w 996 <arg>
Power Output Control Parameter
Note: If Power Control is ENABLED, changes to this
parameter will NOT take effect until Power Control is
DISABLED.
WARNING: Do not set below 36 to avoid PA
damage. This parameter intended for Lab/
Development use only!
255
0
(Do not
set below
36!)
255
Power Leveling Enable
r 997
w 997
Return/Set the value of Power Leveling.
Enable=1/Disable=0.
Note: Power Control (parameter 992) must also be
enabled for Power Leveling to be performed
101
Carrier Feedthrough
Nulling Type
r 998
w 998 <arg>
Nulling Type Parameter. Specifies what type of
nulling will be performed.
0 = Disabled (Nulling must be done manually
periodically via RFO FIPS: a 74 command)
1 = Auto Null (during empty InFLEXion frames or
due to ambient temp change)
2 = DC Offset Training (for FLEX/ReFLEX only)
200
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 7 of 27)
Name and Command
Description
Ranges
Default
Upper Lower