User Manual

Table Of Contents
FIPS Read/Write Commands (ver. 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
E-6 6880493G02-C July 2000
Phase Training Scale
r 982
w 982 <arg>
Return/Set the parameter used by the Collector DSP
to scale the amplitude of the training waveform sent
to the Txlin on the Exciter.
This parameter should be set according to the
number of PA’s installed in the transmitter:
Single PA: Param 982 = -10000
Two PA’s: Param 982 = -14000
Note: If Power Control is ENABLED, changes to this
parameter will NOT take effect until Power Control is
DISABLED.
WARNING: This parameter intended for Lab/
Development use only!
-5000 -32767
-10000
(single PA)
-14000
(dual PA)
K Factor
r 990
w 990 <arg>
Return/Set the parameter used as a fine power level
scaling in the Collector DSP.
Note: If Power Control is ENABLED, changes to this
parameter will NOT take effect until Power Control is
DISABLED.
WARNING: This parameter intended for Lab/
Development use only!
1.0 0.0 1.0
Spectrum Invert
r 991
w 991 <arg>
Return/Set the parameter used by the Collector DSP
to modify the IQ data stream.
1 = Inverted
0 = Non-Inverted
WARNING: This parameter intended for Lab/
Development use only!
101
Power Control Enable
r 992
w 992 <arg>
Return/Set the value of Power Control Enable=1/
Disable=0.
Note: This Parameter is ENABLED upon reset.
Note: If Power Control is ENABLED, changes to
certain parameters will NOT take effect until Power
Control is DISABLED. These parameters include
953, 954, 974, 982, 990, 996, 2053, 2054, 2055,
2056.
WARNING: This parameter intended for Lab/
Development use only!
101
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 6 of 27)
Name and Command
Description
Ranges
Default
Upper Lower