User Manual

Table Of Contents
FIPS Read/Write Commands (ver. 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
E-2 6880493G02-C July 2000
Internal Wattmeter
Forward Power
Minimum Limit
r 141
w 141 <arg>
This command returns/sets the internal wattmeter
forward power minimum limit. If the internal
wattmeter forward power per-subchannel power
goes below this amount, an error will be logged. This
value should be set to one-half of the normal internal
forward power reading.
600 W 0 W 0 W
Internal Wattmeter
Forward Power
Maximum Limit
r 142
w 142 <arg>
This command returns/sets the internal wattmeter
forward power maximum limit. If the internal
wattmeter forward power goes above this amount,
an error will be logged. This values should be set to
two times that of the normal internal forward power
reading.
600 W 0 W 600 W
Internal Wattmeter
Reflected Power
Maximum Limit
r 143
w 143 <arg>
This command returns/sets the external wattmeter
reflected power maximum limit. If the internal
wattmeter per-subchannel reflected power goes
above this amount, an error is logged, and the
transmitter is disabled (shutdown). This value should
be 10% (one-tenth) of the normal internal forward
power reading.
600 W 0 W 600 W
External Wattmeter
Forward Power
Minimum Limit
r 144
w 144 <arg>
This command returns/sets the external wattmeter
forward power minimum limit. If the external
wattmeter per-subchannel forward power goes
below this amount an error will be logged. This value
should be set to one-half of the normal external
forward power reading.
600 W 0 W 0 W
External Wattmeter
Forward Power
Maximum Limit
r 145
w 145 <arg>
This command returns/sets the external wattmeter
forward power. If the external wattmeter per-
subchannel forward power goes above this amount
an error is logged. This values should be set to two
times that of the normal external forward power
reading.
600 W 0 W 600 W
External Wattmeter
Reflected Power Limit
r 146
w 146 <arg>
This command returns/sets the external reflected
power. If the external wattmeter per-subchannel
reflected power goes above this amount, an error is
logged, and the transmitter is disabled (shutdown).
This value should be 10% (one-tenth) of the normal
external forward power reading.
600 W 0 W 600 W
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 2 of 27)
Name and Command
Description
Ranges
Default
Upper Lower