User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
FIPS Read/Write Commands (ver. 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
E-2 6880493G02-C July 2000
Internal Wattmeter
Forward Power
Minimum Limit
r 141
w 141 <arg>
This command returns/sets the internal wattmeter
forward power minimum limit. If the internal
wattmeter forward power per-subchannel power
goes below this amount, an error will be logged. This
value should be set to one-half of the normal internal
forward power reading.
600 W 0 W 0 W
Internal Wattmeter
Forward Power
Maximum Limit
r 142
w 142 <arg>
This command returns/sets the internal wattmeter
forward power maximum limit. If the internal
wattmeter forward power goes above this amount,
an error will be logged. This values should be set to
two times that of the normal internal forward power
reading.
600 W 0 W 600 W
Internal Wattmeter
Reflected Power
Maximum Limit
r 143
w 143 <arg>
This command returns/sets the external wattmeter
reflected power maximum limit. If the internal
wattmeter per-subchannel reflected power goes
above this amount, an error is logged, and the
transmitter is disabled (shutdown). This value should
be 10% (one-tenth) of the normal internal forward
power reading.
600 W 0 W 600 W
External Wattmeter
Forward Power
Minimum Limit
r 144
w 144 <arg>
This command returns/sets the external wattmeter
forward power minimum limit. If the external
wattmeter per-subchannel forward power goes
below this amount an error will be logged. This value
should be set to one-half of the normal external
forward power reading.
600 W 0 W 0 W
External Wattmeter
Forward Power
Maximum Limit
r 145
w 145 <arg>
This command returns/sets the external wattmeter
forward power. If the external wattmeter per-
subchannel forward power goes above this amount
an error is logged. This values should be set to two
times that of the normal external forward power
reading.
600 W 0 W 600 W
External Wattmeter
Reflected Power Limit
r 146
w 146 <arg>
This command returns/sets the external reflected
power. If the external wattmeter per-subchannel
reflected power goes above this amount, an error is
logged, and the transmitter is disabled (shutdown).
This value should be 10% (one-tenth) of the normal
external forward power reading.
600 W 0 W 600 W
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 2 of 27)
Name and Command
Description
Ranges
Default
Upper Lower