User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
RF-Orchestra!™ Transmitter Installation and Operation / Appendix E
July 2000 6880493G02-C E-1
FIPS Read/Write Commands
(ver. 2.0.0) E
This appendix summarizes the Friendly Integrated Paging System (FIPS) read and write
commands for the RF-Orchestra! transmitter. These commands are used to display or modify
the values of the parameters stored in the RF-O! transmitter parameter database.
Table E-1: RF-O! Transmitter Parameters—Read/Write Commands (Sheet 1 of 27)
Name and Command
Description
Ranges
Default
Upper Lower
Paging Access
Disabled
r 99
w 99 <arg>
Paging Access Disable is used to locally disable the
transmitter. If the transmitter is not already disabled,
writing this parameter to ‘1’ will cause the transmitter
to cease transmission. The DISABLE LED will light,
the PWR CTBK LED will start blinking, and the
TX_OK output to the RFB will change to the “Not
OK” state. To re-enable paging access, and there
are no other disables active, write this parameter to
‘0’.(See also, a 83, or parameter 100)
100
Paging Disabled Status
r 100
Gives the current disabled status of the station. If the
transmitter is disabled by the software, the value
read will be a number other than 0.
0xFFFFF
FFF
00
FIPS Inactivity Timer
r 136
w 136 <arg>
Return/Set the Inactivity Timer which will cause the
host to exit FIPS if no keystrokes are recorded
during the elapsed time in this parameter.
3600 s 60 s 300 s
FIPS Baud Rate
r 140
w 140 <arg>
This command returns/sets the communications
data rate of the FIPS port. The following arguments
apply:
1 = 1200 bps 5 = 19200 bps
2 = 2400 bps 6 = 38400 bps
3 = 4800 bps 7 = 57600 bps
4 = 9600 bps 8 = 115200 bps
814