User Manual

Table Of Contents
D-26 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-26 6880493G02-C July 2000
Disable Trace
Mode
a 193 NNNN x
Note: NNNN
syntax is case
sensitive
Use above arguments to disable traces previously
enabled with the RFO FIPS: a 192 command.
RFO FIPS: a 193 RFCQ 1
RFO FIPS: RA 193
RFO FIPS:
Set Subchannel
Frequency
Offsets
a 195 x x x x
Set the subchannel frequency offsets for Test
Modes.
x = 0..3, 13..15
0 = 0 khz
1 = 6.25 khz, 13 = -18.75 khz
2 = 12.50 khz, 14 = -12.50 khz
3 = 18.75 khz, 15 = - 6.25 khz
RFO FIPS: a 195 1 2 3 1
RFO FIPS: RA 195
<<< SET SUBCHANNEL FREQUENCY OFFSETS >>>
Subchannel Frequency Offsets Set to: 1, 2, 3, 1
For Subchannels 1 Through 4, Respectively.
Where:
13 = -18.75 kHz, 14 = -12.50 kHz, 15 = -6.25 kHz
0 = 0.00 kHz
1 = 6.25 kHz, 2 = 12.50 kHz, 3 = 18.75 kHz
Set RF channel
a 196 x
Set the RF Channel to use when keying in Test
Modes.
x = channel (range: 0..15)
Note: RF Channels 0 through 15, are set to the
Center Frequencies programmed in parameter
2000 through 2015, respectively.
RFO FIPS: a 196 1
RFO FIPS: RA 196
RFO FIPS: RA 196
<<< SET TEST CHANNEL >>>
Test Channel Set to 1.
RFO FIPS: a 196 ?
RFO FIPS: RA 196
<<< SET TEST CHANNEL >>>
Usage: A 196 x
x = RF Channel (0..15)
Name and
Command
Description Example