User Manual

Table Of Contents
D-25 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-25 6880493G02-C July 2000
Enable Trace
Mode
a 192 NNNN x
Note: NNNN
syntax is case
sensitive
Note: Enabling
traces CAN
affect station
performance...
use traces with
caution. Be sure
to turn off all
unused traces.
Enables a mode which will output the occurrence of certain events to the
FIPS session. The arguments are:
NNNN x (Trace Enabled)
DIAG 1 - Diagnostic Error Log Trace
SPIQ 1 - SPI Activity
SHMI 1 - Power Supply Status
SHMI 2 - Ambient Temperature Status
SHMI 4 - P/A Temperature Status
SHMI 8- Reserved
SHMI 16 - USHO Present Debug
SHMI 32- Pendulum Locked Debug
SHMI 64 - Pendulum Present Debug
SHMI 128 - Exciter Synth 1 Locked Debug
SHMI 256 - Exciter Synth 2 Locked Debug
DIDQ 1 - Start Time Error
DIDQ 2 - Incomplete Frame Error
DIDQ 4 - Modulation Type Error
DIDQ 8 - Frequency Offset Error
DIDQ 16 - Invalid Command Type
DIDQ 32 - Control Command Format Error
DIDQ 64 - Unexpected Symbol Command Error
DIDQ 126 - Symbol Data Command Format Error
DIDQ 256 - End of Command Error
DIDQ 512 - Workahead Window Error
DIDQ 1024 - Check Command Format Error
DIDQ 2048 - Invalid Symbol Duration
MPCM 16 - Remote Software Download Trace
ITCM 1 - K Factor Trace
ITCM 2 - Attenuation Level Trace
ITCM 4 - Cutback Mode Trace
ITCM 8 - PA Deck Trace
ITCM 16 - Power Supply Trace
ITCM 32 - Carrier Null Trace
SPCQ 1 - Protocol Trace
SPCQ 2 - Reserved
SPCQ 4 - Reserved
SPCQ 8 - DSP Flush Frame State Trace
SPCQ 16 - Power Leveling Trace
SPCQ 32 - VSWR Checking Trace
RFCQ 1 - Control Command Trace
RFO FIPS: a 192 SPCQ 16
RFO FIPS: RA 192
RFO FIPS: a 192 SHMI 1
RFO FIPS: RA 192
RFO FIPS:
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.22 Volt(s)
<SPCQ 16> LEVELING: Set=100 W Act=103 W
Lvl Chg=-0.13 dB Total= 1.57 dB
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.24 Volt(s)
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.24 Volt(s)
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.22 Volt(s)
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.24 Volt(s)
<SHMI 1> PS: PS1=left: PS2=right
PS1=> 4.22 Volt(s): PS2=> 4.24 Volt(s)
Name and
Command