User Manual

Table Of Contents
D-24 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-24 6880493G02-C July 2000
Exciter A/D Read
a 188 y
This action command reads the Exciter A/D
channel specified by argument, y.
y = A/D channel (0x00-0x0B or 0x0C to return all
channels).
RFO FIPS: a 188 c
RFO FIPS: RA 188
<<< READ EXCITER A/D >>>
Reg 00: A+ (14V) = 108 => 14.20 Volt(s)
Reg 01: Rect IF = 036 => 0.70 Volt(s)
Reg 02: 10 V = 167 => 10.18 Volt(s)
Reg 03: CHG Freq 1 = 003 => PASS (> 0)
Reg 04: 5V Analog = 128 => 4.99 Volt(s)
Reg 05: LO2 Lock 2 = 252 => PASS (> 200)
Reg 06: LO2 Lock 1 = 252 => PASS (> 200)
Reg 07: EX Temp = 113 => 40.48 Deg(s) C
Reg 08: A/D Ref = 125 => 2.44 Volt(s)
Reg 09: CHG Freq 2 = 003 => PASS (> 0)
Reg 0A: Epot Wiper = 253 => 4.93 Volt(s)
Reg 0B: A/D Test = 128 => PASS (> 127)
==========================================
Note: The example shown is assuming a of
current
+10; volt +5; and power at +10 .
Name and
Command
Description Example