User Manual

Table Of Contents
D-22 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-22 6880493G02-C July 2000
Read Tranlin
a 172
This action command returns the current register
settings in the Tranlin IC.
RFO FIPS: a 172
RFO FIPS: RA 172
<<< READ TXLIN IC >>>
Reg 0x00: Invert I/Q = 0x16
Reg 0x01: ASW/PWRC = 0x0e
Reg 0x02: LOA = 0x54
Reg 0x03: LON = 0x31
Reg 0x04: LOR = 0xf1
Reg 0x05: Interval A = 0x14 => 125.00 usec
Reg 0x06: Interval B = 0x27 => 243.75 usec
Reg 0x07: Interval C = 0x00 => 0.00 usec
Reg 0x08: Interval D = 0xca => 1262.50 usec
Reg 0x09: Interval E = 0xcc => 1275.00 usec
Reg 0x0A: Interval F = 0x51 => 506.25 usec
Reg 0x0B: Interval G = 0x7e => 787.50 usec
Reg 0x0C: Interval H = 0xcb => 1268.75 usec
Reg 0x0D: Interval I = 0x40 => 400.00 usec
Reg 0x0E: Interval J = 0x20 => 200.00 usec
Reg 0x0F: Interval K = 0xff => 1593.75 usec
Reg 0x10: Interval L = 0x36 => 337.50 usec
Reg 0x11: Interval M = 0x4d => 481.25 usec
Reg 0x12: IQ Slew = 0x00
Reg 0x13: Pmode/DAC = 0x1f
Reg 0x14: PDAC = 0x7f
Reg 0x15: Ph/Lvl/Loop = 0x13
Reg 0x16: Attenuator = 0x00
Reg 0x17: Manual Sin = 0x00
Reg 0x18: Manual Cos = 0x00
Reg 0x19: Interval N = 0x10 => 100.00 usec
Calculated Checksum = 0x07a8
Actual Checksum = 0x07a8
Information = 0x02
Attenuation = 0xff
Sine = 0xfe
Cosine = 0x96
==========================================
Name and
Command
Description Example