User Manual

Table Of Contents
D-18 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-18 6880493G02-C July 2000
Carrier Null
Characterization
a 90 x y z t u
Null the Carrier Feedthrough Component of the
signal.
x = parameter id (979 = i offset; 980 = q offset)
y = Txlin register $12 value (0 ... 255)
z = step count (minimum of 10)
t = beginning offset (-3000 ... 3000)
u = ending offset (-3000 ... 3000)
Note: This was the original command used to null
the carrier. Use command RFO FIPS: a 74
instead.
RFO FIPS: A 90 ?
Please wait. Command in process...
RA 90
<<< CARRIER NULL CHARACTERIZATION >>>
Usage: A 90 x y z t u
x = parameter ID: 979 for i offset, 980 for q offset.
y = Txlin reg $12 value: 00 to ff.
z = Step count: minimum 10.
t = Beginning offset: -3000 to 3000.
u = Ending offset: -3000 to 3000.
Ending offset must be greater than beginning offset.
See FIPS document for more information.
=============================================
RFO FIPS: a 90 979 4 200 0 3000
Please wait. Command in process...
RA 90
200 0 92
200 200 118
200 400 145
200 600 172
200 800 200
200 1000 217
200 1200 218
200 1400 218
200 1600 218
200 1800 218
200 2000 218
200 2200 218
200 2400 218
200 2600 218
200 2800 218
200 3000 218
RFO FIPS:
Name and
Command
Description Example