User Manual
Table Of Contents
- Human Exposure Compliance 1
- Introduction 1
- System Description 2
- Wireless Messaging System Overview
- FLEX, ReFLEX, and InFLEXion Messaging Protocol Overview
- RFO! Transmitter Functional Description
- RFO! Paging Station Options
- Hardware Options
- Software Options
- Network Peripheral Options (Option X267)
- RF-Baton! Transmitter Controller without GPS Receiver (Option X594)
- RFB! Transmitter Controller with GPS Receiver (Option X179)
- Battery Revert (Option X649)
- RFO! Transmitter Peripheral Options (Option X263)
- RFA! Receiver (Option X349, X351, X352, X353)
- RFA! Receiver Peripheral Package (Option X88, X89)
- Equipment Specifications
- Electrical Requirements
- Preinstallation 3
- Installation 4
- Operation 5
- Establishing an RF-O! FIPS Session
- Reset and Initialization
- Operation Modes
- Alarm and Error Logs
- General Operational Setup and First Time Use
- RF-O! Paging Station Parameters
- RF-O! Power Control
- Power Metering
- Wattmeter Calibration
- Amplitude Alignment
- Power Set
- Module Monitoring
- Power Cutback/Shutdown
- Power Leveling
- Alarm Reporting
- Subchannel Configuration Control
- Power Amplifier Configuration Control
- Carrier Feedthrough Nulling
- RF-O! Ambient Temperature Monitoring
- High Ambient Temperature Cutback/Shutdown Operation
- High PA vs. Ambient Temperature Cutback/Shutdown Operation
- Maintenance 6
- Troubleshooting
- Check Front Panel Indications
- Verify Data from the RFB! Transmitter Controller
- RFO! Transmitter Status
- Power Cutback LED is Blinking
- Power Cutback LED is Continuously Illuminated
- Check for Plug-and-Play Errors
- Check Control Data Received by the RFO! Transmitter
- Check RF Power Path
- Check Transmitter Frequency
- Check RF-A! Receiver Functionality
- Pages Not Received
- Voice Quality Diagnostics
- Removal and Replacement
- Cabinet Doors Removal
- Cabinet Doors Replacement
- DC-DC Converter Removal
- DC-DC Converter Installation
- Orchestra Control Board Removal
- Orchestra Control Board Installation
- Exciter Removal
- Exciter Installation
- Power Amplifier Removal
- Power Amplifier Installation
- Power Supply Removal
- Power Supply Installation
- Wattmeter (Power Detector) Removal
- Wattmeter (Power Detector) Installation
- Battery Removal
- Battery Installation
- AC Distribution Panel Removal
- AC Distribution Panel Installation
- RFO! Transmitter Backplane Removal
- RFO! Transmitter Backplane Installation
- RF-A! Receiver Removal and Replacement
- RFB! Transmitter Controller Removal and Replacement
- Resetting the Parameter Database
- Paging Station Alignment
- Temperature Calibration Procedure
- Software Download
- Troubleshooting
- Abbreviations and Acronyms A
- Backplane Connectors B
- Model and Options Charts C
- FIPS Action Commands (ver 2.0.0) D
- FIPS Read/Write Commands (ver.2.0.0) E
- Alarms and Error Messages F
- Transmitter Alignment Checklist G
- Debug Traces H
D-12 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-12 6880493G02-C July 2000
Station Status
a 83
Display the current status of the station.
This command displays the current status of Power
Control, Amplitude Alignment, Internal and External
Wattmeter Calibration, Power Cutback State, Paging
Disabled Status, and Power Leveling.
Note: If any of the Alignments or Calibrations are
INVALID, the RFO should be aligned or calibrated.
Note: If the Power Leveling amount is greater than 0.5
dB or less than -0.5 dB, this tends to signal that the
Amplitude Alignment is not accurate. If the Amplitude
Alignment is accurate, then the Internal Wattmeter
needs to be re-calibrated.
Note: If any of the Disable Sources are ACTIVE, the
transmitter will not key until the cause of the disable is
cleared. Check the Alarm and Error Log (RFO FIPS: a
99 and a 104) for details on any active Disable Source.
RFO FIPS: a 83
RFO FIPS: RA 83
<<< STATION STATUS/MODE >>>
Power Control (R 992)........ENABLED Power Leveling (R 2999)........ 0.00dB
Int Wattmeter Calibration....VALID Ext Wattmeter Calibration......VALID
Amplitude Alignment..........VALID CFT Nulling....................VALID
POWER CUTBACK STATE.......FULL_POWER
PA Temperature............FULL_POWER Ambient Temperature.......FULL_POWER
PA Deck/Power Supply......FULL_POWER Disabled Status...........FULL_POWER
PAGING DISABLED STATUS (R 100 = 0 = 0h)
Paging Access Disabled (R 99)..OK Power Supply A/D Read..........OK
OCM Ambient Temperature........OK Exciter Synthesizer Lock.......OK
Txlin Local Oscillator Lock....OK AM Clipping....................OK
FM Clipping....................OK PA A/D SPI Read................OK
PA Current.....................OK 28 Volt Reference..............OK
14 Volt Reference..............OK UHSO Present/Operating.........OK
Pendulum Lock..................OK Pendulum Present...............OK
Exciter SPI Read...............OK Circulator Load Thermal Limit..OK
PA Failure.....................OK PA Temperature.................OK
Amplitude Alignment............OK Power Leveling Failure.........OK
Internal Wattmeter VSWR........OK High Int WM Reflected Power....OK
External Wattmeter VSWR........OK High Ext WM Reflected Power....OK
External 1PPS Signal...........OK RFB REQ Line Down..............OK
PNP Error......................OK PNP Check Error................OK
Internal Service Mode..........OK
RFO FIPS:
Name and
Command
Description Example