User Manual

Table Of Contents
D-12 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-12 6880493G02-C July 2000
Station Status
a 83
Display the current status of the station.
This command displays the current status of Power
Control, Amplitude Alignment, Internal and External
Wattmeter Calibration, Power Cutback State, Paging
Disabled Status, and Power Leveling.
Note: If any of the Alignments or Calibrations are
INVALID, the RFO should be aligned or calibrated.
Note: If the Power Leveling amount is greater than 0.5
dB or less than -0.5 dB, this tends to signal that the
Amplitude Alignment is not accurate. If the Amplitude
Alignment is accurate, then the Internal Wattmeter
needs to be re-calibrated.
Note: If any of the Disable Sources are ACTIVE, the
transmitter will not key until the cause of the disable is
cleared. Check the Alarm and Error Log (RFO FIPS: a
99 and a 104) for details on any active Disable Source.
RFO FIPS: a 83
RFO FIPS: RA 83
<<< STATION STATUS/MODE >>>
Power Control (R 992)........ENABLED Power Leveling (R 2999)........ 0.00dB
Int Wattmeter Calibration....VALID Ext Wattmeter Calibration......VALID
Amplitude Alignment..........VALID CFT Nulling....................VALID
POWER CUTBACK STATE.......FULL_POWER
PA Temperature............FULL_POWER Ambient Temperature.......FULL_POWER
PA Deck/Power Supply......FULL_POWER Disabled Status...........FULL_POWER
PAGING DISABLED STATUS (R 100 = 0 = 0h)
Paging Access Disabled (R 99)..OK Power Supply A/D Read..........OK
OCM Ambient Temperature........OK Exciter Synthesizer Lock.......OK
Txlin Local Oscillator Lock....OK AM Clipping....................OK
FM Clipping....................OK PA A/D SPI Read................OK
PA Current.....................OK 28 Volt Reference..............OK
14 Volt Reference..............OK UHSO Present/Operating.........OK
Pendulum Lock..................OK Pendulum Present...............OK
Exciter SPI Read...............OK Circulator Load Thermal Limit..OK
PA Failure.....................OK PA Temperature.................OK
Amplitude Alignment............OK Power Leveling Failure.........OK
Internal Wattmeter VSWR........OK High Int WM Reflected Power....OK
External Wattmeter VSWR........OK High Ext WM Reflected Power....OK
External 1PPS Signal...........OK RFB REQ Line Down..............OK
PNP Error......................OK PNP Check Error................OK