FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-11 6880493G02-C July 2000
Read All
Wattmeters
a 80
Displays the latest keyed FM power readings of all
four wattmeter ports, as well as the number of
subchannels active during the last key.
RFO FIPS: a 80
RFO FIPS: RA 80
<<< READ FM POWER OUTPUT >>>
========= RFO WATTMETER READINGS =========
Last Keyed FM Power Readings:
Internal Forward: 95 watts
Internal Reflected: 0 watts
External Forward: 0 watts
External Reflected: 92 watts
Number of Subchannels: 1
---------------------------------------------
The Accuracy of Each Meter is +- 10 %.
==========================================
Read Exciter
Temperature
a 81
Displays the station temperature, at the exciter, in
degrees Celsius.
Note: Read parameter 1026 to determine the
temperature at the OCM temperature sensor
(Ambient Temperature).
RFO FIPS: a 81
RFO FIPS: RA 81
<<< EXCITER TEMPERATURE DATA >>>
---- One-Second Sample(s) ----
00: 0x66 0x66 0x66 0x66 0x66
05: 0x66 0x66 0x66 0x66 0x66
10: 0x66 0x66 0x66 0x66 0x66
15: 0x66 0x66 0x66 0x66 0x66
20: 0x66 0x66 0x66 0x66 0x66
25: 0x66 0x66 0x66 0x66 0x66
30: 0x66 0x66 0x66 0x66 0x66
35: 0x66 0x66 0x66 0x66 0x66
40: 0x66 0x66 0x66 0x66 0x66
45: 0x66 0x66 0x66 0x66 0x66
50: 0x66 0x66 0x66 0x66 0x66
55: 0x66 0x66 0x66 0x66 0x66
---------------------------------------------
Count = 34
---- One-Minute Average(s) ----
00: 0x66 0x66 0x66 0x66 0x66
---------------------------------------------
Count = 01
Exciter Avg Temperature = 0x66 => 34.54 Degrees C
============================================
Name and
Command
Description Example