User Manual

Table Of Contents
D-10 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-10 6880493G02-C July 2000
Subchannel
Delay
a 77 x
Set the subchannel simulcast delay.
x = Subchannel Delay (0..9F hex - 125
microsecond increments)
(if station is dekeyed)
RFO FIPS: a 77 80
RFO FIPS: RA 77
<<< SUBCHANNEL DELAY >>>
The Subchannel Delay is Set to 0x80.
(if station is keyed)
RFO FIPS: a 77 80
RFO FIPS: RA 77
<<< SUBCHANNEL DELAY >>>
The Station Must be Dekeyed to Change the Subchannel Delay.
(request format)
RFO FIPS: a 77 ?
RFO FIPS: RA 77
<<< SUBCHANNEL DELAY >>>
Usage: A 77 x
x = Subchannel Delay (0..9F hex - in 125 Microsecond Increments)
Read Station
Power
a 79 x
Reads the FM Power Level at the selected
wattmeter/detector:
x = Detector Selected
0 = Internal Forward
1 = Internal Reflected
2 = External Forward
3 = External Reflected
y = Power Reading (optional)
no arg = full power - zero
reference
0 = zero reference reading
1 = full power reading
Note: Due to the nature of AM modulation, the
RFO does not monitor AM power output. The AM
power output amplitude is determined by an
algorithm based on the FM power output.
RFO FIPS: a 79 0
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= INTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 105 Watts
Total Wattmeter Voltage: +1.34 Volts
Average FM Keyed Readings (over last 20 keyups):
Power Per Subchannel: 101 Watts
Calibration Factor: 1.009681
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================
Name and
Command
Description Example