User Manual

Table Of Contents
D-9 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-9 6880493G02-C July 2000
Align the Station
Power Amplitude
a 76 x
Align the station power using the power meter as
a reference.
Key the station prior to running this command,
with a single channel of FM modulation. (Use
RFO FIPS: a 176 0 8 0 0 0 1 10 5 1).
x = Current Power Reading (in watts)
Note: Power Control (Parameter 992) must be
DISABLED prior to running this command.
Note: It is important that RFO FIPS: a 75
(Initialize Amplitude Alignment) be performed
immediately prior to this command.
Note: Previous software (prior to 1.2.0) had a
parameter to specify AM vs. FM. AM power
output is derived from FM alignment.
See Chapter 6, "Maintenance",paragraph,
"Transmitter Power Alignment"
RFO FIPS: a 76 82
RFO FIPS: RA 76
<<< ALIGNMENT PARAMETER VALUES >>>
K-Factor 990 = 0.408269
Fdback Atten 996 = 255
Phase Trng 982 = -1
Txlin Reg2 954 = 0
Txlin Reg1 953 = 14
Txlin Atten 974 = 0
Mod Dev 2053 = 4800
FM Power Lvl 2054 = 28000
AM Pilot Pwr 2055 = 1600
AM Sdbd Pwr 2056 = 12426
==========================================
Name and
Command
Description Example