User Manual

Table Of Contents
D-8 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-8 6880493G02-C July 2000
Initialize
Amplitude
Alignment
Parameters
a 75
Initialize the Amplitude Alignment parameters to
default values.
This command must be performed prior to
Amplitude Alignment (RFO FIPS: a 76) or
Wattmeter Calibration (RFO FIPS: a 71).
Note: AM Amplitude alignment is derived from the
FM alignment automatically by the software.
Previous software had a parameter to specify AM
vs. FM.
RFO FIPS: a 75
RFO FIPS: RA 75
<<< ALIGNMENT PARAMETER DEFAULT VALUES >>>
K-Factor 990 = 0.408269
Fdback Atten 996 = 255
Phase Trng 982 = -1
Txlin Reg2 954 = 84
Txlin Reg1 953 = 14
Txlin Atten 974 = 0
Mod Dev 2053 = 4800
FM Power Lvl 2054 = 28000
AM Pilot Pwr 2055 = 1600
AM Sdbd Pwr 2056 = 12426
==========================================
Name and
Command