User Manual

Table Of Contents
D-7 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-7 6880493G02-C July 2000
Exciter EEPROM
Write
a 72 y z1 z2 z3 z4
Writes to the Serial EEPROM on the Exciter.
Write the 4 byte region, using arguments ‘z’,
specified in argument ‘y’.
y = EEPROM Region to be written in hex.
z1,z2,z3,z4 = bytes to be written to the
EEPROM in hex.
WARNING: This command intended for Lab/
Development use only!
RFO FIPS: a 72 0 44 45 54 30
RFO FIPS: RA 72
<<< WRITE EXCITER EEPROM >>>
Exciter EEPROM Cell 0x00 = 0x44 0x45 0x54 0x30
Exciter EEPROM
Read
a 73 y
Reads the 4 byte segment of Exciter Serial
EEPROM specified by argument ‘y’.
y = EEPROM Region to be read in hex (range
0..3f hex)
RFO FIPS: a 73 0
RFO FIPS: RA 73
<<< READ EXCITER EEPROM >>>
Exciter EEPROM Cell 0x00 = 0x44 0x45 0x54 0x30
Txlin Carrier Null
a 74 [x]
Null the carrier feedthru component of the center
channel frequency, where x = 0, 1, 2, 3
Usage:
a74- Performs a Long Null if there is no table, or
Medium Null if a valid table exists.
a 74 0 - Long Null (Over complete range)
a 74 1 - Medium Null (Uses existing table)
a 74 2
- Short Null (Smaller range)
a 74 3 - Half (very short) Null (finds 979 or 980)
Note: Parameters (0,1,2, and 3)were added for
testing purposes. Typically RFO FIPS: a 74 is
used with no parameters.
RFO FIPS: a 74
RFO FIPS: RA 74
<<< CARRIER NULL TABLE >>>
------- (Table Valid) --------
$12 0x0c 0x04 0x08 0x00
-------------------------------------
979 0 -200 0 -200
980 0 0 900 900
Vif 0.16 0.16 0.16 4.21
==========================================
Name and
Command
Description Example