User Manual

Table Of Contents
D-6 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-6 6880493G02-C July 2000
Calibrate
Detector(s)
a 71 x y
Calibrate the Internal/External detector(s)
x = detector
0 = internal
1 = external
y = power value from Wattmeter (in watts)
Note: This command is normally executed
following the RFO FIPS: a75(Initialize Amplitude
Alignment Parameters) command execution.
Power Control must be DISABLED for this
command to function (RFO FIPS: w 992 0).
See Chapter 6, "Maintenance".
Note: This command can take up to 2 minutes to
fully execute. The printing of the Output Report,
shown in the example, will indicate completion of
the command. Do not type any other FIPS
commands while calibration is occurring.
RFO FIPS: a 71 0 210
Please wait. Command in process...
RA 71
<<< CALIBRATE DETECTORS >>>
========= Detector 0 Calibration =========
0x00: 0x44 0x45 0x54 0x30 "DET0"
0x01: 0x30 0x32 0x31 0x30 "0210"
0x02: 0x32 0x2e 0x36 0x36 "2.66"
0x03: 0x32 0x30 0x35 0x34 "2054"
0x04: 0x44 0x45 0x54 0x30 "DET0"
0x05: 0x44 0x45 0x54 0x30 "DET0"
0x06: 0x44 0x45 0x54 0x30 "DET0"
0x07: 0x44 0x45 0x54 0x30 "DET0"
0x08: 0x44 0x45 0x54 0x30 "DET0"
0x09: 0x44 0x45 0x54 0x30 "DET0"
0x0a: 0x44 0x45 0x54 0x30 "DET0"
0x0b: 0x44 0x45 0x54 0x30 "DET0"
0x0c: 0x31 0x2e 0x30 0x2e "1.0."
0x0d: 0x31 0x20 0x00 0x00 "1 .."
0x0e: 0x30 0x30 0x30 0x31 "0001"
0x0f: 0x43 0x48 0x4b 0x9e "CHK."
0x3f: 0x43 0x48 0x4b 0x26 "CHK&"
Calibration Factor = 1.011365
==========================================
Name and
Command
Description Example