User Manual

Table Of Contents
D-4 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-4 6880493G02-C July 2000
Read PA A/D 01
a 68 v w x y z
This action command reads the first of two A/Ds
(analog/digital) on the PA specified by argument v.
Will read the A/D channel specified by argument
w; will read during x modulation type, y number of
times after a delay of z seconds.
v = P/A number (range 1...2)
w = A/D channel (0x00-0x0B or 0x0C to return all
channels)
x = Modulation type
0 = None
1 = FM only
2 = FM and AM
3 = AM only
y = Repetition Rate
z = Delay (seconds)
RFO FIPS: a 68 1 c 0 1 0
RFO FIPS: RA 68
<<< READ PA DECK 01 A/D 01 >>>
Reg 00: PDPA = 077 => 0.11 Amp(s)
Reg 01: DPA = 096 => 2.73 Amp(s)
Reg 02: OD = 032 => 14.50 Watt(s)
Reg 03: FPA 1 A = 099 => 2.53 Amp(s)
Reg 04: FPA 1 B = 097 => 2.92 Amp(s)
Reg 05: FPA 2 A = 088 => 2.14 Amp(s)
Reg 06: FPA 2 B = 093 => 2.53 Amp(s)
Reg 07: FPA 3 A = 091 => 2.53 Amp(s)
Reg 08: FPA 3 B = 095 => 2.92 Amp(s)
Reg 09: Fwd = 068 => 78.6 Watt(s)
Reg 0A: Rfltd = 003 => 0.43 Watt(s)
Reg 0B: A/D Test = 128 => PASS (> 127)
==========================================
Name and
Command
Description Example