User Manual

Table Of Contents
D-3 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-3 6880493G02-C July 2000
PA EEPROM
Read
a 66 x y
Reads the 4 byte segment specified by argument
‘y’ Serial EEPROM from the P/A specified in
argument ‘x’
x = P/A Number (range 1..2)
y = EEPROM Region to be read in hex.
RFO FIPS: a 66 1 0x00
RFO FIPS: RA 66
<<< READ PA EEPROM >>>
PA 1 EEPRM Cell 0x00 = 0x05 0x06 0x07 0x08
PA EEPOT Write
a67xyssawpw
Writes to the EEPOTs of the P/A’s.
x = PA number (range 1..4)
y = phase/attenuation cell (range 0..3)
ss = Stack Select (range 0..1)
aw = Attenuation Wiper (range 0..FF hex)
pw = Phase Wiper (range 0..FF hex)
Note: To reset the PA to the EEPROM settings
tenter RFO FIP: a 67 x 0 where x is the PA
number.
WARNING: This command intended for Lab/
Development use only!
RFO FIPS: a 67 ?
RFO FIPS: RA 67
<<< PA EEPOT WRITE >>>
Usage: A 67 x y ss aw pw
x = PA Number (Maximum 4 for Current Configuration)
y = Phase/Attenuation Cell (0..3)
ss = Stack Select (0..1)
aw = Attenuation Wiper (0..ff hex)
pw = Phase Wiper (0..ff hex)
RFO FIPS: a 67 1 0 0 AF 2F
Name and
Command
Description Example