User Manual

Table Of Contents
D-2 6880493G02-C July 2000
FIPS Action Commands (ver 2.0.0) RF-Orchestra!™ Transmitter Installation and Operation
D-2 6880493G02-C July 2000
Table 4-1: RF-O! Transmitter Parameters -- Action Commands
Name and
Command
Description Example
Limited Self
Diagnostics
a 62
Performs a Limited Set of Tests on the RF-
Orchestra. Will return a Pass or Fail result for
each of the Tests. The Station must be reset
immediately following the execution of this action
command.
RA 62
RFO FIPS: a 62
RFO FIPS:
BEGINNING RFO SELF-DIAGNOSTIC:
Hardware Version ID = 6
DIP switches: #1 OFF #2 OFF #3 OFF #4 OFF
10MHz input connected...................PASSED
16.8MHz Pendulum detected...............PASSED
Pendulum Locked to UHSO.................PASSED
Pendulum temperature = 29C..............NORMAL
Exciter A+ = 13.60V.....................PASSED
Exciter 10V source = 10.11V.............PASSED
Exciter Analog 5V = 5.06V...............PASSED
Exciter Synthesizer 1 Lock..............PASSED
Exciter Synthesizer 2 Lock..............PASSED
Distributor Memory......................PASSED
Modulator 1 Memory......................PASSED
Modulator 2 Memory......................PASSED
Collector Memory........................PASSED
RFO SELF-DIAGNOSTIC.....................PASSED
The station will require a RESET (A 117) after
use of this command
RA 62