RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-99
30. Compare the values in Step 29 with the values stored in Table 6-8. If the previous
operational values are desired instead of the default values now stored for each
parameter, update the parameter value using the appropriate w yyy xxx command from
the RFO FIPS session.
The yyy in the command is the parameter number, and the xxx in the command is the
updated value. Examples are shown below for each parameter, but the values stored in
Table 6-8 should be used instead of the xxx shown below.
Note: These commands only have to be executed if the default values now loaded in these parameters
(see Step 29) are not the desired values. For any parameter that uses the default parameter
values, the associated FIPS write command (w yyy xxx, where yyy is the parameter number
and xxx is the parameter value) shown below is not necessary.
RFO FIPS: r 1024
RFO FIPS: RR 1024 xxx
RFO FIPS: w 141 xxx
RFO FIPS: RR 141 xxx
RFO FIPS: w 142 xxx
RFO FIPS: RR 142 xxx
RFO FIPS: w 143 xxx
RFO FIPS: RR 143 xxx
RFO FIPS: w 144 xxx
RFO FIPS: RR 144 xxx
RFO FIPS: w 145 xxx
RFO FIPS: RR 145 xxx
RFO FIPS: w 146 xxx
RFO FIPS: RR 146 xxx
RFO FIPS: w 997 xxx
RFO FIPS: RR 997 xxx
RFO FIPS: w 1023 xxx
RFO FIPS: RR 1023 xxx
RFO FIPS: w 1024 xxx
RFO FIPS: RR 1024 xxx