24. After about 5 to 15 minutes the following trace should appear on the RFO FIPS session:
25. The number of packets written should keep increasing during a successful download.
For example, the rfo113 image will continue increasing up to 8200 records downloaded
before an automatic cutover occurs. The number of records to download is release
dependent, and should be provided in future release notes. The software download will
take approximately 25 to 30 minutes.
26. On the RFO FIPS session, if the Software Records Downloaded does not appear to be
increasing, verify that no SWDNLD or TFTP errors are logged in the a 110 or a 104 error
logs on the RF-B! transmitter controller. This is verified by typing a 110 and a 104 on the
RFB FIPS session and reviewing any error messages returned. If there are any
Maintenance Path error messages in the log and the download packet message does not
appear to be incrementing on the RFO FIPS session, then the download process has been
disrupted.
27. Once the download completes, the RF-O! transmitter will execute an automatic cutover.
If the RFO FIPS session cutover was successful, the startup banner should appear as
follows:
RFB FIPS: r 432
RFB FIPS: RR 432 200
<MPCM 16> SFWR DNLD: Status: 100 Software Records Downloaded
<MPCM 16> SFWR DNLD: Status: 200 Software Records Downloaded
<MPCM 16> SFWR DNLD: Status: 300 Software Records Downloaded
RFB FIPS: a 104
RFB FIPS: a 110
CAUTION
DO NOT RESET THE RF-O! transmitter. Resetting the RF-O! transmitter in this
state could cause the paging station to disable. This would require a site visit to
replace the RF-O! Flash Memory SIMM.