User Manual

Table Of Contents
Maintenance RF-Orchestra!™ Transmitter Installation and Operation
6-82 6880493G02-C July 2000
Note: If the PA does not read within the above parameters, review setup and calibration. If setup and
calibration were done correctly, and readings are out of range, the PA deck may need to be
replaced. Contact One-Call Support
TM
.
4. Turn off the OCM test mode (dekey) using the RFO FIPS command: a 177
Final Checkout/Restore Station Service
1. Clear the error logs with the RFO FIPS commands: a 111, a 113, and a 103
RFO FIPS: a 68 2 c 1 1 0
RFO FIPS: RA 68
<<< READ PA DECK 02 A/D 01 >>>
Reg 00: PDPA = 078 => 0.11 Amp(s)
Reg 01: DPA = 090 => 2.48 Amp(s)
Reg 02: OD = 025 => 8.45 Watt(s) <--- Should be 015 to 027(if 75W)
Reg 03: FPA 1 A = 088 => 1.42 Amp(s)
Reg 04: FPA 1 B = 087 => 1.77 Amp(s)
Reg 05: FPA 2 A = 084 => 1.42 Amp(s)
Reg 06: FPA 2 B = 102 => 1.77 Amp(s)
Reg 07: FPA 3 A = 086 => 1.42 Amp(s)
Reg 08: FPA 3 B = 080 => 1.77 Amp(s)
Reg 09: Fwd = 046 => 38.14 Watt(s) <--- Should be 036 to 052(if 75W)
Reg 0A: Rfltd = 000 => 0.25 Watt(s)
Reg 0B: A/D Test = 128 => PASS (> 126)
=============================================
RFO FIPS:
RFO FIPS: a 177
RFO FIPS: RA 177
The Station is Dekeyed.
RFO FIPS: a 111
RFO FIPS: a 113
RFO FIPS: a 103