User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-81
3. If you have a two-PA configuration, Type OCM command: a 68 1 c 1 1 0 (to read PA #1)
and a 68 2 c 1 1 0 (to read PA #2). If the station is set for 75W FM power, verify the
following values are in the given range for BOTH PAs.
a. Register 02 should be 021 ± 6 (for 75W FM power)
b. Register 09 should be 044 ± 8 (for 75W FM power)
Reg 02: OD = 030 => 7.68 Watt(s) <--- Should be 026 to 038 (if 75W)
Reg 03: FPA 1 A = 093 => 2.13 Amp(s)
Reg 04: FPA 1 B = 098 => 2.48 Amp(s)
Reg 05: FPA 2 A = 084 => 2.13 Amp(s)
Reg 06: FPA 2 B = 100 => 2.30 Amp(s)
Reg 07: FPA 3 A = 089 => 2.13 Amp(s)
Reg 08: FPA 3 B = 094 => 2.66 Amp(s)
Reg 09: Fwd = 066 => 78.51 Watt(s) <--- Should be 059 to 075(if 75 W)
Reg 0A: Rfltd = 001 => 0.37 Watt(s)
Reg 0B: A/D Test = 128 => PASS (> 126)
=============================================
RFO FIPS: a 68 1 c 1 1 0
RFO FIPS: RA 68
<<< READ PA DECK 01 A/D 01 >>>
Reg 00: PDPA = 091 => 0.11 Amp(s)
Reg 01: DPA = 097 => 2.48 Amp(s)
Reg 02: OD = 021 => 9.04 Watt(s) <--- Should be 015 to 027(if 75W)
Reg 03: FPA 1 A = 095 => 1.42 Amp(s)
Reg 04: FPA 1 B = 090 => 1.59 Amp(s)
Reg 05: FPA 2 A = 085 => 1.24 Amp(s)
Reg 06: FPA 2 B = 096 => 1.59 Amp(s)
Reg 07: FPA 3 A = 095 => 1.42 Amp(s)
Reg 08: FPA 3 B = 088 => 1.59 Amp(s)
Reg 09: Fwd = 047 => 39.03 Watt(s) <--- Should be 036 to 052(if 75W)
Reg 0A: Rfltd = 002 => 0.51 Watt(s)
Reg 0B: A/D Test = 128 => PASS (> 126)
=============================================
RFO FIPS: