User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-79
17. Read the external Forward Wattmeter using the RFO FIPS command: a 79 2
18. Set the External Wattmeter Forward Power Minimum Limit to 50% of the external
forward power reading (Power Per Subchannel) using the FIPS command: w 144 x (for a
reading of 60 watts x is 30).
19. Set the External Wattmeter Forward Power Maximum Limit to two times that of the
external forward power reading (Power Per Subchannel) using the FIPS command: w 145
x (for a reading of 60 watts x is 120).
20. Set the External Wattmeter Reflected Power Limit to 10% of the external forward power
reading (Power Per Subchannel) using the FIPS command: w 146 x (for a reading of 60
watts x is 6).
RFO FIPS: a 79 2
RFO FIPS: RA 79
<<< FM POWER OUTPUT READINGS >>>
========= EXTERNAL FORWARD WATTMETER =========
Last Keyed FM Readings:
Total Station Power: 60 Watts
Total Wattmeter Voltage: +0.96 Volts
Average FM Keyed Readings (over last 20 keyups):
Power Per Subchannel: 60 Watts <----------------Use this reading
for next 3 steps.
Calibration Factor: 0.936122
---------------------------------------------
The Accuracy of This Meter is +- 10 %.
=============================================