6-74 6880493G02-C July 2000
5. Initialize amplitude alignment parameters with the RFO FIPS command: a 75
6. Key the transmitter in test mode with following RFO FIPS command: a176080001105
1
RFO FIPS: a 75
RFO FIPS: RA 75
<<< ALIGNMENT PARAMETER DEFAULT VALUES >>>
K-Factor 990 = 0.408269
Fdback Atten 996 = 255
Phase Trng 982 = -10000
Txlin Reg2 954 = 84
Txlin Reg1 953 = 14
Txlin Atten 974 = 0
Mod Dev 2053 = 4800
FM Power Lvl 2054 = 28000
AM Pilot Pwr 2055 = 1600
AM Sdbd Pwr 2056 = 12426
=============================================
RFO FIPS: a 176 0 8 0 0 0 1 10 5 1
RFO FIPS: RA 176
<<< RFO TEST MODES >>>
The Station is Keyed in Test Mode.