User Manual

Table Of Contents
RF-Orchestra!™ Transmitter Installation and Operation Maintenance
July 2000 6880493G02-C 6-73
18. Turn off the OCM test mode (dekey) using the FIPS command: a 177
19. Disconnect the characterized coupler from the top of the cabinet and connect the Tx
output to the 500 watt 50 ohm load.
Transmitter Power Alignment
This procedure assumes that the wattmeters were previously calibrated. The factory sets this
value at 75 Watts, but the value is user-configurable.
1. Ensure that the RF-O! transmitter is terminated into a 500-Watt, 50-ohm load.
2. Confirm that the RF-O! transmitter is disconnected from the network.
3. Reaccess the RF-O! transmitter, if necessary:
4. Ensure power-control is turned off with the RFO FIPS command: w 992 0
RFO FIPS: a 177
RFO FIPS: RA 177
The Station is Dekeyed.
RFO FIPS:
ENTER PROTOCOL
fips
ENTER PASSWORD
6000
RFO FIPS:
RFO FIPS: w 992 0
RFO FIPS: RW 992 0